{"product_id":"flash-lamp-finemec-noblex-nobleen-p160001","title":"Flash Lamp, FineMEC Noblex, Nobleen | P160001","description":"\u003ch2\u003eFlash Lamp (UK) for FineMEC Noblex, Nobleen\u003c\/h2\u003e\n\u003cp data-end=\"382\" data-start=\"40\"\u003e\u003cspan class=\"BZ_Pyq_fadeIn\"\u003eFineMEC Part Number Reference: P160001\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThis \u003cstrong\u003eUK-made Alexandrite flash lamp\u003c\/strong\u003e fits both of FineMEC's long-pulsed \u003cstrong\u003e755 nm Alexandrite\u003c\/strong\u003e platforms: the single-source \u003cstrong\u003eNoblex\u003c\/strong\u003e and the dual-wavelength \u003cstrong\u003eNobleen\u003c\/strong\u003e. FineMEC — one of the first Korean manufacturers to bring long-pulsed Alex and Nd:YAG lasers to the global aesthetic market — built the Nobleen by combining the Noblex Alexandrite source with the Aileen Nd:YAG source on one chassis. Because both systems share the same Alexandrite laser architecture, the Alex-side flash lamp is the same part across both platforms.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhat makes this lamp's role distinctive is FineMEC's \u003cstrong\u003eFine Square Shape Beam Technology\u003c\/strong\u003e — a square-pulse delivery profile that requires consistent, flat-topped discharge across the full pulse duration. With pulse widths configurable from \u003cstrong\u003e0.2 to 300 ms\u003c\/strong\u003e in single, double, or triple-pulse mode, output up to \u003cstrong\u003e80 J\u003c\/strong\u003e, and repetition rates up to \u003cstrong\u003e10 Hz\u003c\/strong\u003e, the lamp operates across an unusually wide energy and timing envelope. As the lamp ages, the first symptoms typically appear as pulse-shape degradation — uneven energy delivery within longer pulses, instability at higher repetition rates, or reduced peak output at the larger 15–20 mm spot sizes where the system is most demanding. \u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThis replacement lamp is selected for stable square-pulse behavior, consistent discharge across the full pulse-width range, and reliable operation at sustained 10 Hz firing.  During installation, technicians should inspect the lamp seating, reflector surface, RCS gas-cooling lines or air-cooling path, electrical contacts, and aiming-beam alignment before returning the system to clinical use.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eTechnical Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Laser Flash Lamp\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eApplication area:\u003c\/strong\u003e FineMEC Alexandrite laser cavity (755 nm long-pulsed) — Noblex single-source, Nobleen Alexandrite side\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eSupported pulse modes:\u003c\/strong\u003e Single, double, and triple pulse (0.2–300 ms)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Pumps the Alexandrite rod while supporting Fine Square Shape Beam pulse profile up to 10 Hz\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCommon replacement reasons:\u003c\/strong\u003e low energy error, reduced output, ignition delay, quartz darkening, unstable discharge, electrode wear, or end-of-life performance drop\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new replacement part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis part is compatible with the following devices:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFineMEC Noblex\u003c\/li\u003e\n\u003cli\u003eFineMEC Nobleen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt LaserX Parts, we carefully select and quality-check every product to ensure only premium-quality spare parts reach our customers.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.8em;\"\u003eLaserX Parts is an independent supplier of spare parts for professional laser and aesthetic devices. We are not affiliated with, authorized by, or endorsed by any of the brands mentioned on this site. All brand names, trademarks, and logos are the property of their respective owners and are used solely to identify product compatibility.\u003c\/span\u003e\u003c\/p\u003e","brand":"Finemec","offers":[{"title":"Default Title","offer_id":45561882607806,"sku":null,"price":335.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/7692\/5886\/files\/Photo_1762336931833_56db7e97-4f36-49a0-922c-03c2dc5fced3.jpg?v=1765548186","url":"https:\/\/laserxparts.com\/products\/flash-lamp-finemec-noblex-nobleen-p160001","provider":"LaserX Parts","version":"1.0","type":"link"}